{"id":10271,"date":"2019-08-23T14:25:13","date_gmt":"2019-08-23T07:25:13","guid":{"rendered":"https:\/\/unilead-asia.com\/?post_type=product&#038;p=10271"},"modified":"2024-04-30T08:17:54","modified_gmt":"2024-04-30T01:17:54","slug":"moxa-mgate-3280-serial-to-ethernet-modbus-gateways","status":"publish","type":"product","link":"https:\/\/unilead-asia.com\/index.php\/product\/moxa-mgate-3280-serial-to-ethernet-modbus-gateways\/","title":{"rendered":"MOXA Mgate 3280 Serial-to-Ethernet Modbus Gateways"},"content":{"rendered":"<div class=\"module-block module-block--white\">\n<h3 class=\"module-block__heading\">Introduction<\/h3>\n<p class=\"module-block__paragraph\">The MB3180, MB3280, and MB3480 are standard Modbus gateways that convert between Modbus TCP and Modbus RTU\/ASCII protocols. Up to 16 simultaneous Modbus TCP masters are supported, with up to 31 RTU\/ASCII slaves per serial port. For RTU\/ASCII masters, up to 32 TCP slaves are supported.<\/p>\n<\/div>\n<div class=\"module-block module-block--white\">\n<h4 class=\"module-block__subheading\">Standard Modbus Network Integration<\/h4>\n<p class=\"module-block__paragraph\">The three standard MGate\u2122 models (MB3180, MB3280, and MB3480) are designed for easy integration of Modbus TCP and RTU\/ASCII networks. With these models, Modbus serial slave devices can be seamlessly incorporated into an existing Modbus TCP network, and Modbus TCP slaves can be made accessible to serial masters. The MB3180, MB3280, and MB3480 offer features that make network integration easy, customizable, and compatible with almost any Modbus network.<\/p>\n<\/div>\n<div class=\"module-block module-block--white\">\n<h4 class=\"module-block__subheading\">High Density, Cost-Effective Gateways<\/h4>\n<p class=\"module-block__paragraph\">The MGate\u2122 MB3000 gateways can effectively connect a high density of Modbus nodes to the same network. The MB3280 can manage up to 62 serial slave nodes, and the MB3480 can manage up to 124 serial slave nodes. Each RS-232\/422\/485 serial port can be configured individually for Modbus RTU or Modbus ASCII operation and for different baudrates, allowing both types of networks to be integrated with Modbus TCP through one Modbus gateway.<\/p>\n<\/div>\n<div class=\"module-block module-block--white\">\n<h4 class=\"module-block__subheading\">Auto-Device Routing for Easy Configuration (Patent Pending)<\/h4>\n<p class=\"module-block__paragraph\">Moxa\u2019s Auto-Device Routing function helps eliminate many of the problems and inconveniences encountered by engineers who need to configure large numbers of Modbus devices. A single mouse click is all that\u2019s required to set up a slave ID routing table and configure Modbus gateways to automatically detect Modbus requests from a supervisory control and data acquisition (SCADA) system. By removing the need to manually create the slave ID routing table, the Auto-Device Routing function saves engineers significant time and cost.<\/p>\n<\/div>\n<h4>Features and Benefits<\/h4>\n<p>Supports Auto Device Routing for easy configuration<\/p>\n<p>Supports route by TCP port or IP address for flexible deployment<\/p>\n<p>Converts between Modbus TCP and Modbus RTU\/ASCII protocols<\/p>\n<p>1 Ethernet port and 2 RS-232\/422\/485 ports<\/p>\n<p>16 simultaneous TCP masters with up to 32 simultaneous requests per master<br \/>\nEasy hardware setup and configuration<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<ul class=\"i-list\">\n<li class=\"i-list__item\"><span class=\"i-list__text\">Supports Auto Device Routing for easy configuration<\/span><\/li>\n<li class=\"i-list__item\"><i class=\"i-list__icon i-list__icon--green icon-check\"><\/i>\u00a0<span class=\"i-list__text\">Supports route by TCP port or IP address for flexible deployment<\/span><\/li>\n<li class=\"i-list__item\"><i class=\"i-list__icon i-list__icon--green icon-check\"><\/i>\u00a0<span class=\"i-list__text\">Converts between Modbus TCP and Modbus RTU\/ASCII protocols<\/span><\/li>\n<li class=\"i-list__item\"><i class=\"i-list__icon i-list__icon--green icon-check\"><\/i>\u00a0<span class=\"i-list__text\">1 Ethernet port and 1, 2, or 4 RS-232\/422\/485 ports<\/span><\/li>\n<li class=\"i-list__item\"><i class=\"i-list__icon i-list__icon--green icon-check\"><\/i>\u00a0<span class=\"i-list__text\">16 simultaneous TCP masters with up to 32 simultaneous requests per master<\/span><\/li>\n<li class=\"i-list__item\"><i class=\"i-list__icon i-list__icon--green icon-check\"><\/i>\u00a0<span class=\"i-list__text\">Easy hardware setup and configuration<\/span><\/li>\n<\/ul>\n","protected":false},"featured_media":10268,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[211],"product_tag":[208,210,207,195],"_links":{"self":[{"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/product\/10271"}],"collection":[{"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/comments?post=10271"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/media\/10268"}],"wp:attachment":[{"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/media?parent=10271"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=10271"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=10271"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}