{"id":41718,"date":"2024-04-25T10:31:08","date_gmt":"2024-04-25T03:31:08","guid":{"rendered":"https:\/\/unilead-asia.com\/?post_type=product&#038;p=41718"},"modified":"2026-03-31T09:48:25","modified_gmt":"2026-03-31T02:48:25","slug":"industrial-4-port-rs232-rs422-rs485-serial-device-server","status":"publish","type":"product","link":"https:\/\/unilead-asia.com\/index.php\/product\/industrial-4-port-rs232-rs422-rs485-serial-device-server\/","title":{"rendered":"PLANET ICS-2400T Industrial 4-Port RS232\/RS422\/RS485 Serial Device Server"},"content":{"rendered":"<p><strong>Cost-effective Solution for RS232\/422\/485 Serial-to-Industrial Ethernet Application<\/strong><\/p>\n<p>PLANET ICS-2400T Serial Device Server is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking so as to extend the network distance efficiently and inexpensively. There are two 10\/100BASE-TX RJ45 ports available in the ICS-2400T for your network needs. The ICS-2400T is a time-saving and cost-effective solution for users and system integrators to quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.planet.com.tw\/storage\/products\/49215\/edm_ICS-2200T_ICS-2400T.jpg\" \/><\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.planet.com.tw\/storage\/products\/49215\/ICS-2200T_2400T-1.png\" \/><\/p>\n<p><strong>Remote Management\u00a0<\/strong><\/p>\n<p>As the ICS-2400T provides an easy serial-to-Ethernet connectivity and connection to a TCP\/IP network, the remote network system can thus be managed efficiently via its Web, telnet and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator\u2019s time in detecting and locating network problems without visual inspection of the cabling and devices.\u00a0 Multiple connection options are available for large networking environment as well.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.planet.com.tw\/storage\/products\/49215\/ICS-2200T_2400T-2.png\" \/><\/p>\n<p><strong>Stable Performance under Difficult Environments<\/strong><\/p>\n<p>The ICS-2400T provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the ICS-2400T to be placed in almost any difficult environment.<\/p>\n<p>The ICS-2400T, equipped with compact IP40 standard metal case, allows either DIN-rail or wall mounting for efficient use of cabinet space.\u00a0 The ICS-2400T also provides an integrated power supply source with a wide range of voltages (12 to 48V DC) ideally suitable for worldwide operation with high availability applications requiring dual or backup power inputs.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dual Power Input for High Availability Network System<\/strong><\/p>\n<p>The ICS-2400T features a strong dual power input system with wide-ranging voltages (12V~48V DC) incorporated into customer\u2019s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the ICS-2400T via Power Supply 2 without any break of operation.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.planet.com.tw\/storage\/products\/49215\/ICS-2400T-1.png\" \/><\/p>\n<table class=\"table table-sm table-bordered table-striped-gray table-header-no-border table-header-theme-gray table-bordered-inside-only\">\n<thead>\n<tr>\n<th colspan=\"2\">Ordering Information<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"text-center align-middle\">\n<h3 class=\"h6 m-0\">ICS-2400T<\/h3>\n<\/td>\n<td>Industrial 4-port RS232\/RS422\/RS485 Serial Device Server<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<table class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\">\n<thead>\n<tr>\n<th colspan=\"2\">Serial Interface<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"align-middle\">Serial Ports<\/td>\n<td>4 x DB9 male<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Serial Standards<\/td>\n<td>RS232\/RS422\/4-wire RS485\/2-wire RS485<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Baud Rate (Data Rate)<\/td>\n<td>50bps to 921Kbps<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Data Bits<\/td>\n<td>5, 6, 7, 8<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Parity Type<\/td>\n<td>1, 1.5, 2<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Stop Bit<\/td>\n<td>Odd, Even, None, Space, Mark<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Flow Control<\/td>\n<td>RTS\/CTS and DTR\/DSR (RS232 only)<br \/>\nXON\/XOFF<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Signals<\/td>\n<td>RS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND<br \/>\nRS422: Tx+, Tx-, Rx+, Rx-, GND<br \/>\n4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND<br \/>\n2-wire RS485: Data A (+), Data B (-), GND<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Pin Assignment<\/td>\n<td>\n<table class=\"table-bordered-bone\" cellpadding=\"6\">\n<tbody>\n<tr>\n<td valign=\"middle\" bgcolor=\"7f9cd3\" width=\"40\"><span style=\"color: #ffffff;\">Pin<\/span><\/td>\n<td valign=\"middle\" bgcolor=\"7f9cd3\" width=\"100\"><span style=\"color: #ffffff;\">RS232<\/span><\/td>\n<td valign=\"middle\" bgcolor=\"7f9cd3\" width=\"100\"><span style=\"color: #ffffff;\">RS422<br \/>\nRS485-4W<\/span><\/td>\n<td valign=\"middle\" bgcolor=\"7f9cd3\" width=\"100\"><span style=\"color: #ffffff;\">RS485-2W<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">1<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">DCD<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">TxD+<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">2<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">RxD<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">TxD-<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">3<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">TxD<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">RxD-<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">Data-<\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">4<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">DTR<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">RxD+<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">Data+<\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">5<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">GND<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">GND<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">GND<\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">6<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">DSR<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">7<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">RTS<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">8<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">CTS<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td valign=\"middle\" bgcolor=\"edf0f7\">9<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<td valign=\"middle\" bgcolor=\"FFFFFF\">&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Serial Line Protection<\/td>\n<td>2KV isolation protection<br \/>\n1.5KV (level 2) surge protection<br \/>\n15KV ESD protection<\/td>\n<\/tr>\n<\/tbody>\n<thead>\n<tr>\n<th colspan=\"2\">Ethernet Interface<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"align-middle\">Ethernet Ports<\/td>\n<td>2 x RJ45<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Standard<\/td>\n<td>10\/100BASE-TX<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Distance<\/td>\n<td>100m<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Switch Architecture<\/td>\n<td>Store-and-Forward<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Address Table<\/td>\n<td>1K<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">ESD Protection<\/td>\n<td>6KV<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Surge Protection<\/td>\n<td>2KV<\/td>\n<\/tr>\n<\/tbody>\n<thead>\n<tr>\n<th colspan=\"2\">Hardware<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"align-middle\">Installation<\/td>\n<td>DIN-rail kit and wall-mount ear<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Enclosure<\/td>\n<td>IP40 metal<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Dimensions (W x D x H)<\/td>\n<td>50 x 87 x 135 mm<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Weight<\/td>\n<td>625 g<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">LED Indicators<\/td>\n<td>System: Power 1, Power 2, Fault, I\/O<br \/>\nTP Port: Link\/Active<br \/>\nSerial Port: Tx and Rx<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Power Requirements<\/td>\n<td>12~48V DC, redundant power with polarity reverse protection function<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Power Consumption<\/td>\n<td>Full Loading<br \/>\n12VDC: 0.419A (5.1 watts)<br \/>\n24VDC: 0.227A (5.4 watts)<br \/>\n48VDC: 0.136A (6.5 watts)<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Connector<\/td>\n<td>Removable 6-pin terminal block for power input<br \/>\nPin 1\/2 for Power 1, Pin 3\/4 for fault alarm, Pin 5\/6 for Power 2<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">DI and DO<\/td>\n<td>2 Digital Input (DI):<br \/>\nLevel 0: -24V~2.1V (\u00b10.1V)<br \/>\nLevel 1: 2.1V~24V (\u00b10.1V)<br \/>\nInput Load to 24V DC, 10mA max.2 Digital Output (DO):<br \/>\nOpen collector to 24V DC, 100mA max.<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Alarm<\/td>\n<td>Provides one relay output for power failure<br \/>\nAlarm relay current carry ability: 1A @ DC 24V<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Reset Button<\/td>\n<td>&lt; 5 sec: System reboot<br \/>\n&gt; 5 sec: Factory default<\/td>\n<\/tr>\n<\/tbody>\n<thead>\n<tr>\n<th colspan=\"2\">Management<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"align-middle\">Management Interfaces<\/td>\n<td>Web management<br \/>\nTelnet Console management<br \/>\nWindows-based VCOM Utility management<br \/>\nPLANET Smart Discovery Utility<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">IP Version<\/td>\n<td>IPv4 and IPv6<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Operation Mode<\/td>\n<td>TCP Server<br \/>\nTCP Client<br \/>\nUDP Client<br \/>\nVirtual COM<br \/>\nRFC2217<br \/>\nTelnet Server<br \/>\nPair Connection \u2013 Remote (Slave)<br \/>\nPair Connection \u2013 Local (Master)<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Virtual COM Utility Platform Supports<\/td>\n<td>Windows Base Only:<br \/>\nWindows XP<br \/>\nWindows Server 2003<br \/>\nWindows 7<br \/>\nWindows Server 2008<br \/>\nWindows 8 (Must install the latest version of WinPcap)<br \/>\nWindows Server 2012 (Must install the latest version of WinPcap)<br \/>\nWindows 10<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Alert<\/td>\n<td>Built-in buzzer and RTC<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Security<\/td>\n<td>Allow max. 4 accessible IP address hosts\/ranges<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">SNMP MIBs<\/td>\n<td>RFC1213 MIB-II<br \/>\nRFC1317 RS232-like MIB<\/td>\n<\/tr>\n<\/tbody>\n<thead>\n<tr>\n<th colspan=\"2\">Standards Conformances<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"align-middle\">Regulatory Compliance<\/td>\n<td>FCC Part 15 Class A,<br \/>\nCE Certification Class A<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Stability Testing<\/td>\n<td>IEC60068-2-32 (Free fall)<br \/>\nIEC60068-2-27 (Shock)<br \/>\nIEC60068-2-6 (Vibration)<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Standards<\/td>\n<td>IEEE 802.3 10BASE-T<br \/>\nIEEE 802.3u 100BASE-TX<br \/>\nIEEE 802.3x flow control and back pressure<br \/>\nRFC 768 UDP<br \/>\nRFC 793 TFTP<br \/>\nRFC 791 IP<br \/>\nRFC 792 ICMP<br \/>\nRFC 854 Telnet<br \/>\nRFC 958 NTP<br \/>\nRFC 1591 DNS (client only)<br \/>\nRFC 1908 SNMPv2c<br \/>\nRFC 2068 HTTP<br \/>\nRFC 2131 DHCP Client<br \/>\nRFC 2732 Format for Literal IPv6 Addresses in URL&#8217;s<br \/>\nRFC 3315 DHCPv6 Client<br \/>\nRFC 3513 IPv6 Addressing Architecture<br \/>\nRFC 3596 DNSv6<br \/>\nRFC 4443 ICMPv6<br \/>\nEIA\/TIA RS232\/422\/485<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Regulatory Approval<\/td>\n<td>RoHS<\/td>\n<\/tr>\n<\/tbody>\n<thead>\n<tr>\n<th colspan=\"2\">Environment<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"align-middle\">Operating Temperature<\/td>\n<td>-40 ~ 75 degrees C<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Storage Temperature<\/td>\n<td>-40 ~ 85 degrees C<\/td>\n<\/tr>\n<tr>\n<td class=\"align-middle\">Humidity<\/td>\n<td>5 ~ 95% (non-condensing)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":41730,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[298,204],"product_tag":[300,336,344],"_links":{"self":[{"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/product\/41718"}],"collection":[{"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/comments?post=41718"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/media\/41730"}],"wp:attachment":[{"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/media?parent=41718"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=41718"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/unilead-asia.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=41718"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}